For
use with M.G. Chemicals photofabrication products for the etching professional
printed circuit boards for prototyping or small production run requirements.
WARNING:
Heating unit must be unplugged to turn off. Do not leave heating unit unattended
while it is in use. Do not let Etching tank run dry. Do not attempt to operate
etching kit if tank is less than 3/4 full. Avoid skin contact with Etchant or
direct breathing of vapor.
Cleanup with warm soapy water. Used etchant should
be placed back into original container, write "waste material" on the container
and dispose of it in an environmentally safe fashion in compliance with local
waste regulations.
M.G. Chemicals cat #416-E Etching Kit contains the following
items:
- A seven liter polyethylene tank with clear acrylic lid
- Mounting
bracket
- #416-AP Heavy Duty Air Pump
- 3 way adjustable airline manifold
- Triple line sparging unit
- #416-AH Air Hose for sparging unit
- #416-H
200 Watt vertical Heater
- External Tank mounted digital thermometer
- #416-G
Latex disposable gloves
- This kit contains no chemical products.
Instructions:
- Mount the heater opposite to the spout end of your etching tank as per diagram
A. DO NOT PLUG IN HEATER.
- Secure the tank within its
mounting bracket and screw the bracket to the surface you will be working on.
With, and sparging unit positioned in the tank, ensure the etchant solution is
filled to the level indicated on the quartz element of heater;
- Wait 15
minutes for the thermostat to adjust itself to the etchant temperature;
- Plug
in the heater;
- The heater's thermostat has been preset to the correct
temperature. However shipping and handling may have effected settings and final
temperature adjusting may be required. The pilot light should turn on and remain
lit until the operating temperature has been reached.
- Allow the heater
to operate for one hour. When the desired temperature is reached the pilot light
will turn off and the heater will maintain the temperature.
Air
Pump Installation:
- Air Pump must be placed above the etching tank
at the highest level of etching solution. This will prevent a backflow of etchant
into the pump, causing damage to the pump and leakage of etchant.
- Connect
the airline to the output on pump. The pump is operational when once plugged into
wall outlet.
Important: Ensure Heater is unplugged and cool
to touch before you remove it or before changing etchant. DO NOT ALLOW
ETCHANT TO RUN DRY. Do not allow etchant level to drop below indicated
"water line" on heater tube.